Type | Channel Passband |
Upgrade Port |
Port | First Channel |
Pigtail | Fiber | Length | Connector (Input-Output) |
Package |
M=Mux D=Demux M+D=Mux+ Demux |
1=100GHz 2=200GHz |
U= Yes 0= No |
1002=1X2 1004=1X4 1008=1X8 1016=1X16 XX=other |
C21 C22 C23 (Refer to ITU Channel Table) |
L=900um loose tube 2=2.0mm 3=3.0mm B= baare fiber A= Adaptor |
S1=G652D S2=G657A1 X= other |
0.5M=0.5M 1M=1M X=other |
SU=SC/UPC SA=SC/APC FU=FC/UPC FA=FC/APC ST=ST/UPC LA=LC/APC LU=LC/UPC 00=NONE XX= Other |
01,02,03,04, 05 H,L,U,G,X |
1CH | 2/4CH | 8CH | 16/18/40/48CH |
05 | 01/L/G/U | 02/L/G/U | 03/L/H/G/U |
04 |
No. | Dimension | No. | Dimension |
05 | Φ5.5×L38 Stainless steel tube | 02 | 120× 80× 18 Plastic box |
04 | 90 X 20 X 9.5 Plastic box | L | 150 × 115 × 18 Aluminum box |
01 | 100 × 80 × 10 Plastic box | W | 150X65X16 |
H | 150 × 115 × 18 Plastic box | Y | 127X70X11 |
B | Φ5.0×L38 Stainless steel tube | U | 19''x=1,2,3,4 U rack mount |
G | LGX box : 1G, 2G, 3G, 4G | X | Customized package |
03 | 141× 115 × 18 Plastic box |
Parameter | 4 Channel | 8 Channel | 16 Channel | |
Channel Wavelength(nm) | 1260~1620 | |||
Channel Spacing(nm) | 20 | |||
Channel Passband (@-0.5dB bandwidth)(nm) | ±6.5 | |||
Insertion Loss(dB) | ≤1.5 | ≤2.5 | ≤3.5 | |
Channel Uniformity(dB) | ≤0.6 | ≤1.0 | ≤1.5 | |
Channel Ripple(dB) | <0.3 | |||
Isolation(dB) | Adjacent | >30 | ||
Non-adjacent | >40 | |||
Insertion Loss Temperature Sensitivity(dB/℃) | <0.005 | |||
Wavelength Temperature Shifting(nm/℃) | <0.002 | |||
Polarization Dependent Loss(dB) | <0.1 | |||
Polarization Mode Dispersion(ps) | <0.1 | |||
Directivity(dB) | >50 | |||
Return Loss(dB) | >45 | |||
Maximum Power Handling(mW) | 300 | |||
Operating Temperature(℃) | -5~+75 | |||
Storage Temperature(℃) | -40~+85 |